Product Description
Guangdong Yongrong New Building Materials Co., Ltd. specializes in manufacturing Yongrong reflective heat insulation coatings. Utilizing nano-level reflective pigments and hollow microsphere technology, it achieves a triple heat insulation mechanism: solar reflectance ≥0.85, efficient heat conduction blocking, and radiative heat dissipation. This significantly reduces building surface temperature by 15-25℃ and saves 20%-40% on air conditioning energy consumption. Suitable for roofs, exterior walls, and industrial facilities, we sincerely invite project owners to purchase in bulk or contact Yongrong directly as a premium supplier for customized reflective heat insulation coatings.
Product Parameter

Product Feature
I. Product Core Positioning and Technical Architecture
1. Product Definition and Technical System
Yongrong Reflective Thermal Insulation Coating Core Components: Acrylic resin or silicone resin as the film-forming material, combined with nano-level reflective pigments (such as titanium dioxide, ceramic microspheres) and hollow glass microspheres as thermal insulation fillers. Technological Breakthrough: Utilizing a multi-layer composite structure, it achieves high-efficiency thermal insulation through a triple mechanism of "reflection-blocking-radiation," achieving a solar reflectance of over 0.85 and a hemispherical emissivity ≥0.89. Environmental Certification: Water-based Yongrong reflective thermal insulation coatings comply with GB 18582-2020 (VOC≤50g/L), solvent-based products comply with GB 30981-2020, and some products have obtained U.S. Energy Star certification.

2. Key Performance Parameter Table
Indicator | Parameter Value | Industry Comparison
Solar Reflectance (GB/T 25261) | ≥0.85 | Ordinary coatings approx. 0.3-0.5
Hemispherical Emissivity (GB/T 13475) | ≥0.89 | Industry average 0.80
Artificial Weathering Resistance (h) | ≥1000 | Ordinary thermal insulation coatings approx. 500h
Thermal Conductivity (W/(m·K)) | ≤0.08 | Traditional coatings approx. 0.15



II. Scenario-Based Solutions
1. Application Scenario Adaptation Matrix
Application Scenario | Core Needs | Recommendation System
Building Roof | High-efficiency thermal insulation + waterproofing | Yongrong reflective thermal insulation topcoat + elastic waterproof primer
Exterior Wall Facade | Decorative + thermal insulation | Reflective thermal insulation intermediate coat + colored reflective topcoat
Industrial Plant | High temperature resistance + corrosion resistance | Organosilicon reflective thermal insulation coating + epoxy primer
Oil Tank/Pipeline | Thermal insulation and cooling + fireproofing High-Temperature Reflective Thermal Insulation Coating + Fire-Retardant Primer



2. Energy-Saving Benefits Analysis
• Cooling Effect: Reduces building surface temperature by 15-25℃ and indoor temperature by 3-8℃ in summer.
• Energy Saving Rate: Reduces air conditioning energy consumption by 20%-40%, with a payback period of approximately 3-5 years.
• Environmental Contribution: Each square meter of Yongrong reflective thermal insulation coating reduces CO₂ emissions by approximately 1.2 kg per year (based on a 30% energy saving rate).



III. Technical Standards and Testing Certification
1. Authoritative Standard System
• Domestic Standards: GB/T 25261-2018 "Reflective Thermal Insulation Coatings for Buildings", GB 18582-2020 (Limits of Hazardous Substances).
• International Standards: ASTM C1549 (Solar Reflectance), EN 1504-2 (Building Protective Products).
• Certification: Provides testing reports from the China Academy of Building Research and U.S. Energy Star certification (optional).



2. Precise Construction Guidelines: Three-Step Substrate Preparation:
(1) Substrate Inspection: The substrate must be flat and dry (moisture content ≤8%), pH value 6.5-7.5.
(2) Pretreatment: New walls should be plastered and sanded to 200 grit. Old walls need to be free of hollow areas and oil stains, and cracks repaired.
(3) Sealing Primer: Spray the matching primer (theoretical consumption 0.15kg/m²), drying for 4-6 hours.



3. Construction Process Parameters:
• Spraying: Pressure 0.4-0.6MPa, nozzle diameter 1.5-2.0mm, 2-3 coats (dry film thickness ≥80μm).
• Roller Application: Use a short-nap roller to avoid sagging, with an interval of 2-4 hours between coats.
• Environmental Control: Construction temperature 5-35℃, humidity <85%, avoid rainy or windy weather.
• Construction Period: Standard roof (1000㎡) requires 5-7 working days, including a 24-hour curing period.






IV. Customized Service Solutions
1. Product Customization Options
• Color System: White, silver, and light-colored series are available (highest reflectivity). Dark-colored products require customization (reflectivity ≥0.6).
• Functional Upgrades: Antibacterial agents (E. coli kill rate ≥99%) and self-cleaning components (contact angle ≥110°) can be added.
• Packaging Specifications: 20 kg/bucket/20 liters (Yongrong dark green 20-liter plastic bucket) 1000 kg/bucket/1000L (Yongrong 1000-liter ton container)
2. Technical Support System
• Pre-sales Service: Free base surface testing and energy-saving effect simulation.
• In-sales Service: Full technical guidance throughout the construction process, with one on-site inspection per 1000㎡.
• After-sales Service: 10-year quality guarantee and 24-hour emergency response.

V. Safety and Compliance Assurance
1. Safety Data Sheet (SDS) Highlights
• Health Hazards: Water-based Yongrong reflective thermal insulation coating is non-irritating; solvent-based products contain a small amount of VOCs (compliant with GB 30981-2020).
• Environmental Impact: Water-based products are biodegradable; solvent-based products must be treated as hazardous waste.
• Storage Conditions: Store at 5-35℃ away from light; shelf life 12 months (water-based) / 18 months (solvent-based).
2. Construction Protection Guidelines
• Personal Protection: Wear a dust mask (KN95 level) and solvent-resistant gloves (when applying solvent-based products).
• Fire and Explosion Prevention: Open flames are strictly prohibited in the application area for solvent-based products; fire extinguishers must be available.
• Waste Disposal: Empty containers must be recycled by a professional hazardous waste disposal company; remaining coatings must be sealed and stored.

VI. Case Studies and Data Support
• Successful Case: A commercial complex used Yongrong reflective thermal insulation coating on its roof, resulting in a 6℃ reduction in indoor temperature in summer and a 35% reduction in air conditioning electricity costs.
• Actual test data: After 3 years of outdoor exposure in Guangzhou, the solar reflectance remains at 0.82, and the hemispherical emissivity is ≥0.87.
• Customer testimonial: An industrial plant reported that after using this product, the surface temperature of the equipment decreased by 20℃, extending the equipment's lifespan by 30%.

Note: The product performance and application data listed above were obtained under specific experimental conditions. However, actual application environments are diverse and not subject to our constraints. If you have any questions, please contact Guangdong Yongrong New Building Materials Co., Ltd. We reserve the right to revise the product manual without further notice.
Send Inquiry